by malfist
1480 days ago
|
|
I've always heard this, but I don't know that that's true. The thing that dies first on an HVAC system isn't the motor, it lasts a long damn time, it's the capacitor, or contactor or some other fault not really related to the motor work load. Plus, your "motor" isn't an engine, it's not variable speed, it only has one "hardness" that it works at. It might push less air with the thicker filter, but it's not going to ramp up and consume more wattage or anything like that. |
|
The problem is (especially with older furnaces; modern ones have safety features to prevent this) that if you have too much back-pressure you don't get enough airflow over the heat exchanger (or air conditioner coils) and it can crack - allowing dangerous exhaust gasses into the airflow (or freezing the coils for the AC which isn't as bad).
Once the heat exchanger is gone the furnace is basically trash and has to be replaced (you can replace the heat exchanger but it's rarely worth it).