by CompelTechnic
4066 days ago
|
|
Is "state feedback" synonymous with P-only control? I've got an intake valve at work that we're controlling with P-only control, It basically iterates based on incremental voltage being proportional to current error in valve position. Just trying to brush up on my lingo. |
|
State-space representation is a strictly time domain approach, where you break your model and controller into a bunch of 1st degree DEs. This method is really only tractable with computing support.
In general, state-space and frequency domain models can in theory accomplish the same goals. You could for many situations design a PID controller using classical methods, and then take the same situation and use a state space approach, and in the end result in the equivalent controller/behavior.