by coned88
4299 days ago
|
|
What I don't understand about the URE is from [2]. If you have a 12TB raid 5 array and you need to rebuild. If 10^14 approaches an URE at around 12TB of data as the article says. What causes it to hit 12TB? Each disk has 10^14 which is 100TB. If you had 12TB from 4x3TB disks it should have alot to go through. |
|
If you have 4x 4TB drives in RAID5, and one fails, then in order to rebuild with a replacement drive, you have to read all data from all surviving drives (3 x 4TB = 12TB).
Here is an example from a manufacturer:
http://www.seagate.com/files/www-content/product-content/con...