That’s largely correct but misses the point that the battery+pv system is legally only allowed to feed in 800W [1]. On our circuits you can draw ~3.5kW without tripping the breaker. This brings you to 4.3kW max load, which - as far as I understand - is still what all the circuitry must be rated for anyways.

The downside is that we have three phase power supply anywhere halfway recent. And that only gives you a single phase. In _most_ cases that’s fine, because you get a net-sum of all three phases at the meter, but technically you are only drawing/supplementing one out of three phases. In practice this likely doesn’t matter since different house put theirs on different phases and it all washes out.

[1] the DC side can have up to 2kW of panels. But that’s not visible to the grid