by max51
13 days ago
|
|
I'm a structural engineer, and this is incorrect. For structural steel (e.g., A992, 350W, etc.), the tensile strength is the same as the compressive strength. That's why we only need one value for both. And yes, when we design beams, we check the stresses in both tension and compression. For a symmetrical shape like an I-shaped beam, both verification will be the exact same formula so we don't need to calculate both explicitly. For columns, we do check the compressive stress, and it is the controlling failure mode for short columns. Long, slender columns will buckle before the compressive stress exceeds the allowable limit. |
|
They are only the same in an abstract theoretical sense, not an actual one.
And bucking within the column (and/or the resistance too it) is primarily resisted by tensile strength.