by z2
83 days ago
|
|
There are non-battery buffers available too--I recently got rooftop residential solar installed, and learned that my area is covered by a grid profile requiring that the solar system stay online through something like 60 +/- 2Hz before shutting down completely, and ramping down production linearly beyond a 1Hz deviation or so. The point is to avoid cascading shutdowns by riding through over/undersupply situations, whereas an older standard for my area would have the all solar systems cut off the moment frequency exceeded 60.5Hz (which would indicate oversupply from power plant generators spinning faster via lower resistance). In my system's case, switching to this grid profile was just a software toggle. |
|
Tesla’s Megapack system at the Hornsdale Power Reserve in Australia was the first example of this being proven out at scale in prod. Batteries everywhere, as quickly as possible.