by kev009
152 days ago
|
|
There are very survivable fiber cables designed for stage and A/V setups for instance, and even "real" military grade ones. But the common thin LZSH stuff is surprisingly resilient in my experience, so long as it didn't kink the OP would probably have been fine with a "standard" cable. In any case I would always try to place fiber in a place where it can be re-pulled.. conduit, tray, or a plenum. I bought a big spool of 6 strand Corning stuff a long time ago for various projects, the cost and diameter don't increase much to add some protection lines even if you never imagine using them they can save you a re-pull if you bugger something up in construction. |
|