|
|
|
|
|
by dlubarov
393 days ago
|
|
Yes, but if it's a much worse insulator, the extra heat transfer through studs might be more significant? I'm not sure if it's been measured, but I imagine this densified wood would probably have at least twice the thermal conductivity of typical construction lumber, since naturally dense hardwoods already approach that. So it seems like we'd basically need to replace 2x studs with 1x studs, assuming the same stud spacing, in order to match the thermal performance of a traditional wall. I don't think this would be a dealbreaker at all though, one could always use continuous insulation instead of cavity insulation, which has a lot of benefits anyway. Maybe it can end up being a competitor to metal studs for commercial builds, at least. |
|