by StillBored
516 days ago
|
|
In areas with moderate outdoor temperatures. Anywhere that the heatpump is going through defrost cycles, that statement is likely false because the COP is likely 1 or less when that starts happening. Then on the generation side, its worse if the NG generation isn't a modern combined cycle plant. which also tends to nix places with a lot of renewable generation because the NG plants are just peaker gas turbines with much lower efficiency than plants designed for continuous use. So, its all situational, but at the same time if one has the choice for cheap NG using that as a second stage and setting the crossover heatpump temperature at the cost/BTU intersection between the heatpump and NG second stage is a rough approximation of the enviromental costs as well as the actual cost. |
|
Modern heat pumps have a COP close to 2 at 5F/-15C while still delivering 50k+ BTUs. Here's one example: https://ashp.neep.org/#!/product/68628/7/25000/95/7500/0///0