by rscott2049
666 days ago
|
|
I did some further investigating - it's apparently due to not having enough setup
time on the RX pio SM. Even though the PIO clocking is fixed at 100 MHz, there are CRC errors at the lower system clocks. I tried changing the delay in the PIO instruction that starts the RX sampling, but that only made things worse (as expected). Also tried disabling the synchronizers with no improvement. |
|
If so, might it be possible to use two RX PIOs, automatically starting the next one via inter-PIO IRQ when a packet is finished? That'd give you an entire packet receive time to reset the original PIO, which should be plenty.