by sokoloff
801 days ago
|
|
The question is not about the general hydronic heating formula [nor manual J heat loss estimations], but rather "what will the delta T of the rad in this particular room, in this piping network [it's a converted gravity feed system, now being a pumped], using 69°F room temp and 135°F leaving water temp from the heat source?" |
|
Alternately, to get a realistic measure, you'll need to set your boundary conditions about what the heat flow out of the room will be, which is a bit simpler to setup with U-values, area, delta-T, and heat capacity of materials. You'll also need to do this to every other room in the building simultaneously. This is a Manual J, or heat balance method or the radiant time series method load calculation that will balance out with the amount of heat leaving your radiator without knowing its specific shape.