by helsinkiandrew
832 days ago
|
|
A maximum of 60% of the winds power can be extracted from wind (Bet'z law [1]) and modern turbines are only capable of catching 80% of that. There's lots of research in optimal spacing. I read that a rule of thumb was 4-5 diameter widths between turbines at right angles to prevailing wind and then 7 diameter widths between rows facing the wind [1] https://en.wikipedia.org/wiki/Betz%27s_law |
|