by PaulDavisThe1st
954 days ago
|
|
COP == 1 is the point at which a heat pump becomes a resistive heater. As COP drops below 1, a heat pump becomes more and more like an actual resistive heater. Nobody is bragging about COP == 1 ... it's just a reference point at which the benefit of a heat pump goes away and it becomes ... just an inefficient heater. |
|
Of course I recognize low temperatures are merely one small portion of the time. Residential heat pump system design has generally taken advantage of this by having backup resistive coils. It would be much more efficient to fall back to a gas furnace, but for the capital cost. So an actual comparison necessarily takes into account expected temperatures over the day and the heating season, likely nighttime setback, thermal mass, etc. Which certainly isn't easy to button up into a simple comparison, but the point is resistive heating is a red herring!