Hacker News new | ask | show | jobs
by ejstronge 1429 days ago
This is not strictly true - there is a transposase based prep that does not require special equipment.

Still, ONT users would need to understand how to convert raw reads into useable basecalls at loci of clinical interest

1 comments

Does it still require a pipettor, or could it work with just a transfer pipet? Their field kit should probably be as minimal as it could be.

Last I looked into it, it was a minimal set of extra equipment -- votexer, centrifuge, etc... nothing unusual for a bio lab. And even most of that could be handled with a good snap of the wrist, if you weren't trying to be super precise.

If one is patient, the only tool needed in the wet lab is a transfer pipettor and a scale - I think this could be done without a micropipettor