Inductive pickup (foreign voltage) from even fairly long runs (20kf +) of well maintained copper is usually much less less than half a volt, measuring either T-R, or T-G/R-G. It's supposed to be floating to ground - nothing on a twisted pair should be ground referenced, if you do have voltage to ground, you have a short.

If it was not floating, you'd get atmospherics, hum, and other issues that you saw in old fashioned ground return systems.

Indeed, measurement of voltage and continuity of T-G and R-G is a standard way to check for faulty cable

1 comments

Unless the telco cut the outer shielding on the twisted pair cables everywhere a terminal was installed. That was one of the remediations the incumbent had to undertake here when they started deploying 50Mbps VDSL2 FTTN service. Oops.