by saltcured
1566 days ago
|
|
Just piling on with more anecdata... This is for a roughly 2k sq foot house in the S.F. (East) Bay Area that was built in the 1970s with gas heat but electric clothes drier. Early in the pandemic, we had a period where it was unoccupied but not really shutdown, i.e. refrigeration continued and lights were on timers for security. I can call this the baseline/idle load. It was about 9.2 kWh per day and 0.3 therms per day of natural gas for the pilot lights and tank-based water heater. When occupied in mild weather, our baseline moves to about 10.2 kWh per day and 0.5 therms of natural gas with cooking and water heater usage. Our peak highest usage for electricity seems to be about 13.2 kWh per day in a summer month with terrible AQI where we had filtration fans running and even deployed a portable A/C due to not being able to do our normal natural cooling of the house. Our peak natural gas usage was around 5.2 therms per day for a cold winter month. Edit to add clarification: these are averages over a 1 month billing period, not instantaneous peak power etc. When looking at finer grained usage, our electricity is quite flat over time with weekly spikes when we run our laundry and dry clothes with electricity. |
|