by withinboredom
1625 days ago
|
|
I have two of the AX41-NVMe, and only one was lucky enough to get a "Intel Corporation I210 Gigabit Network Connection (rev 03)" which has the hardware timestamping. In the finland datacenter, it appears there is a PTP running, though the offset is ~2.33 seconds off from NTP. Chrony says its a false-ticker, but I haven't really figured out how to get it configured correctly nor have I asked Hetzner for help. I've mostly just played around with it. I did manage to also accidentally discover a local ISP's stratum 1's server is extremely close to me, as in a few microseconds away (I accidentally put hetzner's servers as a pool instead of a server and my NTP 'discovered' the stratum 1) ... I'm not using it, but I've thought about reaching out to them to ask if I can use it if I'm very nice. |
|
Is the 2.33s stable? If so, after deducing the stable offset, it could still be valuable.