by Dylan16807
1923 days ago
|
|
RAID0 can't give you a true 2x increase, because reads and writes are constrained to a particular device, and big reads tend to require both drives working together. RAID1 can give you a 2x increase in reads, but suffers even more than RAID0 when it comes to writes. Dual actuators, implemented in a straightforward way, can both access the entire drive surface which means they can give you a true 2x increase. Sometimes even better than 2x, because each arm can focus on one side of the disk. For read/write workloads it completely outclasses RAID. |
|
That constraint means nothing here. You can issue two parallel reads to two drives in RAID-0 just as easily in RAID-1. The only case where this doesn't work is where you're reading more than 2x the interleave size and you're issuing separate requests for each interleaved chunk. With command queuing, a smart storage system should even recognize the pattern and buffer to reduce the damage, but you'll still pay a cost in extra interrupts and request handling though so it's better to learn about scatter/gather lists.
> they can give you a true 2x increase