by tripletao
2108 days ago
|
|
I think battery-powered unintentional radiators can sometimes avoid testing, but battery-powered intentional radiators definitely don't. The statement about kits is also wrong, per pdabbadabba's comment below. An intentional radiator module can get a module certification. In that case the final system still needs verification (the same kind of testing that an unintentional radiator gets), but doesn't need certification. When you see a label on the outer device that says "Contains FCC ID XXX-XXXX", that's the module's ID. https://apps.fcc.gov/oetcf/kdb/forms/FTSSearchResultPage.cfm... |
|