by jimmySixDOF
2175 days ago
|
|
Yes almost anything to do with Industrial Ethernet type standards are all over the place. 1588 PTP mixes with IETF TICTOC workgroup output. Synchronous data also gets used in Psuedowire backhaul for low level circuit emulation signaling like from SCADA or GSM towers etc. And that's without going into IECxxxxx's for powerplant comms. Certifiable Precision Timeing over anything is not trivial. |
|