by rdtsc
5588 days ago
|
|
Good point, however, the problem is only half-solved. If the machine is coldstarted then previous devices could be randomly reshufled. Imagine you have a datacenter with 100 machines and you have some kind of provisioning scheme where you coldstart them often. It would be a nightmare having to run ethtool -p <dev> and replug cables. We have solved the problem by providing a consistent algorithm of sorting all the devices in a udev callback. We have a known set of hardware so we know which cards are add-ons (our machines have 4+ eth ports) and which ones are built-ins. So it works out, however, it would be nice to generalize it somehow. |
|
The detection order would change, but the ifcfg file (RH) or udev rules (SuSE and others) would not change, so your NICs will stay the same these days.