by chrismonsanto
2359 days ago
|
|
> in practice FWIW RISC-V guarantees forward progress for reasonable uses: > We mandate that LR/SC sequences of bounded length (16 consecutive static instructions) will eventually succeed, provided they contain only base ISA instructions other than loads, stores, and taken branches. |
|
what happens if those 16 instructions touch 16 different cache lines? I'm not an hardware expert (and even less on coherency protocols), but I think it would be extremely hard to make sure livelocking is avoided in all cases, short of having some extremely expensive and heavy handed global 'bus' lock fallback.