Hacker News new | ask | show | jobs
by m0xte 2370 days ago
Fuse would be good. Here in UK there’s one in the plug. The 10M resistor will current limit. Or probably flash over here.

Isolation transformer is not required if the enclosure is better. It also doesn’t help you if you stick yourself across it somewhere, only helping yourself with respect to ground. If you’re testing it or doing development with it I would use one. But I wouldn’t build it.

I used to hang around inside old valve radios when I was a kid. You learn respect for high voltages very quickly.

1 comments

Hey you guys, Author of the article here. Thanks for mentioning the issues. I never meant it to go this viral. Crashed my website in the morning. You seem to mention that the output resistor was wrongly chosen. Can you elaborate? I thought I designed it properly. This post was not ever meant to be used without using basic safety features in mind. (Like keep it away from children and all). I will explicitly mention that to be taken care of in the post. Happy to take any more constructive criticisms to make the post better.
Yeah no worries. We’re all hyper critical. Need to outline the dangers because people who are unaware of the issues working with mains tend to be the first to drop dead. This is followed by the people who suffer from Dunning-Kruger effect. Us amateur radio operators like to kill ourselves on vintage power amplifiers doing that.

The output resistor need to handle potential to ground so say 7kv across output to ground. Resistor is rated for 200V working voltage. Usually you use a chain of many smaller resistors here.

I haven’t reviewed the design entirely but the main problem is the enclosure and mains connection and the component choice. The mains connection should be clamped in the enclosure and either spade connections or screw terminals or ferrules. The enclosure should be double insulated. As mentioned a fuse would be a good idea as well.

Always design for worst case with these things.