by throwaway2048
2789 days ago
|
|
Raid 5/6 require parity calculations before data can be written to disk. This is a significant amount of data, especially at high writing speeds. That is what causes the inflight data problem. Battery and flash backup on controllers dosen't fix the problem of hardware failure (which is significant, especially on big hot controllers. |
|
But much of this micro level redundancy is overkill as frequently one uses some kind of application level HA/redundancy as well. So, loss of a RAID5/6 disk in a single machine is the functional equivalent of loss of a any combination of RAID 0/1 in the same machine. You still need the higher level redundancy as well as a backup plan.
We could start breaking the discussion up into fabric attached vs direct attach RAID vs Software, but I think its sufficient to say, that RAID5/6 doesn't _increase_ the failure surface in any meaningful way when your not using fly-by-night RAID.
Edit: Maybe what your trying to say is that cache flush/FUA operations for a give piece of data don't cover the parity calculation and buffers? That is false, a controller should not be responding to FUA/etc until the entire (including the parity) block has been persisted. So if the controller dies during the operation the host OS is fully aware that the operation didn't complete. The given block is of course left in some unknown state in this case, but that is true of any write operation that fails like this, regardless of WT/WB/RAID/etc.