by yil8
2916 days ago
|
|
There was indeed a professional pathologist involved in the Camelyon 16 Challenge, where s/he spent 30 hours reviewing 130 slides, and ended up 72.4% sensitivity with 0 false positives. Our algorithm achieves ~91% sensitive at 8 false positives per slides, seems a win according to your "a lower specificity is an acceptable trade off for a very high sensitivity." |
|