by londons_explore
3388 days ago
|
|
How did you protect against overfitting? How about local maxima? Some of your constants look surprising to say the least. Most notably: * The gamma value of 0.38 (when most studies suggest 1.5 - 2.5 for human eye gamma) * The significant difference in the vertical and horizontal constants (when as far as I know human eyes are equally sensitive to most distortions independant of angle). |
|
In this use the gamma is the inverse of something close to 2.6. Butteraugli needs both gamma correction and inverse gamma correction.